ServiceNow Alerts
Overview
ServiceNow is an IT service management platform that tracks work as records on tables. Its Business Rules engine runs server-side JavaScript whenever a record is inserted or updated. Business Rules can make outbound REST calls with the built-in sn_ws.RESTMessageV2 API, so a ServiceNow instance can call any publicly reachable HTTPS endpoint.
That is all you need to turn a critical ticket into a voice alert in a technician's hand: ServiceNow detects the priority change, posts to the Relay Alerts API, and every device in the target Workflow Group speaks the message until someone taps the talk button to accept the job.
This page builds a complete, working critical incident alert.
Why Alerts and not Broadcasts
Relay offers two notification types. Use Alerts for critical incidents. An alert repeats every 30 seconds until a human acknowledges it, and it records who accepted the job, which is the accountability an urgent ticket needs. A broadcast plays once with no acknowledgement. That is fine for shift announcements, but generally the wrong approach for a critical ticket.
Why a Business Rule and not Flow Designer
ServiceNow's Flow Designer can also call REST endpoints, but its REST step is part of the Integration Hub spoke, which requires an Integration Hub subscription and is not installed on every instance. A Business Rule works on every ServiceNow instance with no additional licensing, so this guide uses one. If your organization already has Integration Hub, you can build the equivalent flow with the same endpoint, header, and JSON body shown below.
Prerequisites
Relay
An enterprise plan account. API keys are not available on lower tiers.
Relay
A Workflow Group containing the users who should receive critical incident calls.
Relay
Your subscriber ID and an API key.
ServiceNow
An instance where you have the admin role (a Personal Developer Instance works for trying this out). This guide was verified on the Brazil release.
ServiceNow
Outbound HTTPS access from the instance to api.relaypro.com. Hosted instances allow this by default; self-hosted or restricted instances may need an egress rule.
Create the Relay Workflow Group
In Relay Dash, open Incidents in the left-hand navigation.
Select Workflow Groups, then Create Workflow Group.
Name the group. This guide uses maintenance.
Set the type to No Type.
Select the new group, choose Edit Membership, and add the users who should be called.
The group name is what ServiceNow will send in the groups array of the API payload.
Collect your Relay credentials
subscriber_id
Relay Dash → Help → Diagnostic Logs → Server Details, listed under Subscriber
apikey
Relay Dash → Help → API Keys → create a key
Store the credentials as System Properties
Keep the subscriber ID, API key, and group name out of the script by storing them as system properties.
In ServiceNow, type sys_properties.list into the navigator filter and press Enter, then select New for each of the following:
relay.subscriber_id
string
Your subscriber ID from Step 2
relay.api_key
password2
Your API key from Step 2
relay.group
string
The Workflow Group name, for example maintenance
Leave Application as Global and select Submit on each.
If relay.group is missing, the script falls back to a group named maintenance.
Create the Business Rule
Type sys_script.list into the navigator filter, press Enter, and select New. Fill in the form as follows.
Name
Relay - Alert on Critical Incident
Table
Incident [incident]
Active
Checked
Advanced
Checked
On the When to run tab:
When
async
Order
100
Insert
Checked
Update
Checked
On the Advanced tab, set Condition to:
Then replace the contents of the Script field with:
Select Submit to save the rule.
Test it end to end
Create a test incident (type incident.do into the navigator filter, or use Incident → Create New):
Set a Caller and a Short description such as
Press 7 on Line B is down.Set Impact to
1 - Highand Urgency to1 - High. Priority recalculates to1 - Critical.Select Submit.
Within a few seconds a device in your Workflow Group should speak:
Critical incident INC0010001. Press 7 on Line B is down. Please respond.
Tap the talk button to acknowledge. The device that accepts hears Accepted. You are assigned to INC0010001. and the other devices in the group stop alerting.
To confirm from the ServiceNow side, open System Logs → System Log → All and filter Message contains Relay alert. A successful call logs:
How the trigger works
The Condition current.priority.changesTo(1) is true when an incident is inserted with Priority 1 or updated so that Priority becomes 1. It does not fire on later edits to a ticket that is already Priority 1, so adding a comment or reassigning the ticket will not page the group again.
Two behaviors to be aware of:
If a ticket moves from Priority 1 to another priority and later back to Priority 1, the rule fires again and a new alert is sent.
Priority is normally calculated from Impact and Urgency. Changing either field can move Priority to 1 and trigger the rule.
Changing what counts as urgent
Edit the Condition on the Business Rule. Some common variations:
Priority 1 or 2
current.priority.changesTo(1) || current.priority.changesTo(2)
High urgency, regardless of priority
current.urgency.changesTo(1)
Priority 1 only for a specific assignment group
current.priority.changesTo(1) && current.assignment_group.name == 'Facilities'
To route different tickets to different Relay groups, replace the group variable in the script with a value computed from the record, for example from current.getValue('category'). The value must match a Workflow Group name (or URN) in Relay Dash.
Payload reference
Relay alert keys
notification and groups are required. Everything else is optional.
notification
string
—
Spoken on every device in the group via text-to-speech.
groups
array
—
Workflow Group names or URNs to alert.
quorum
integer
all devices must acknowledge
Cancels remaining alerts after this many acknowledgements. Set this to 1 for incident calls.
on_ack
string
nothing spoken
Spoken on the device that acknowledged.
on_quorum
string
nothing spoken
Spoken on devices that had not yet acknowledged once quorum is met.
timeout
integer (sec)
300
Cancels remaining alerts after this long.
on_timeout
string
nothing spoken
Spoken on devices that never acknowledged, after timeout.
name
string
alerts
Controls serial/concurrent alerting behavior and appears in analytics events for correlation.
Leaving quorum at its default means the alert keeps sounding on every other device until all of them acknowledge. That is not what you want for an incident call where one technician takes the job. Set quorum: 1.
ServiceNow fields used in the message
The script reads these fields from the incident (current):
current.getValue('number')
Spoken ticket number, for example INC0010001
current.getValue('short_description')
Spoken problem summary
Other fields you can read the same way include priority, category, location, cmdb_ci, and assignment_group. For reference fields such as location, use current.location.getDisplayValue() to get the human-readable name rather than the record's sys_id.
Troubleshooting
Start with the log: System Logs → System Log → All, filter Message contains Relay alert. Every run of the rule writes exactly one line.
No Relay alert line in the log at all
The rule did not run. Check that it is Active, that Insert and Update are checked, and that the incident's Priority actually changed to 1 - Critical in this save. A ticket that was already Priority 1 will not fire.
HTTP 401
The Authorization header is wrong. It must be RelayApiKey <key> with a space. Also confirm the key was copied completely and has not been revoked.
HTTP 400
The request body was rejected. If you changed the script to build JSON by hand, check for unescaped quotes or newlines in interpolated values.
HTTP 404
The subscriber ID in relay.subscriber_id is wrong or has stray whitespace.
Relay alert exception ...
The call never reached Relay (DNS, firewall, or timeout). Confirm the instance can reach api.relaypro.com over HTTPS.
Log says sent, but no device speaks
The alert was accepted, so check the Relay side. The relay.group value must exactly match a Workflow Group name, and that group must have members whose devices are online.
The alert keeps repeating after someone started work
Alerts repeat every 30 seconds until acknowledged on a device or until timeout. Acknowledge on the device, or cancel with the DELETE call in Step 3.
Reference
ServiceNow
Relay
Last updated