Telit DeviceWISE
Overview
Telit deviceWISE Cloud is an industrial IoT platform that models equipment as Things carrying properties, attributes, and alarms. Its Cloud Triggers engine watches for changes to those objects and runs a sequence of actions in response.
One of those actions, http.client, can call any publicly reachable HTTPS endpoint. That is all you need to turn a PLC fault into a voice alert in a technician's hand: deviceWISE detects the alarm, posts to the Relay Alerts API, and every device in the target Workflow Group speaks the message until someone taps the talk button to accept the job.
This page builds a complete, working machine-down alert.
Why Alerts and not Broadcasts
Relay offers two notification types. Use Alerts for machine-down. An alert repeats every 30 seconds until a human acknowledges it and records who accepted the job, which is exactly the accountability a maintenance call needs. A broadcast plays once with no acknowledgement — fine for shift announcements, wrong for downtime.
Prerequisites
Relay
An enterprise plan account. API keys are not available on lower tiers.
Relay
A Workflow Group containing the users who should receive machine-down calls.
Relay
Your subscriber ID and an API key.
Telit
A deviceWISE Cloud organization with the Triggers feature enabled. If /triggers returns "Triggers are not available. Please contact support to enable this feature," Triggers is not provisioned on your org — open a ticket with Telit before going further.
Telit
A Thing representing the machine, publishing an alarm when the machine faults.
Telit
A user with Developer permissions in the org.
Create the Relay Workflow Group
In Relay Dash, open Incidents in the left-hand navigation.
Select Workflow Groups, then Create Workflow Group.
Name the group — this guide uses maintenance.
Set the type to No Type.
Select the new group, choose Edit Membership, and add the users who should be called.
The group name is what you will put in the groups array of the API payload.
Collect your Relay credentials
subscriber_id
Relay Dash → Help → Diagnostic Logs → Server Details, listed under Subscriber
apikey
Relay Dash → Help → API Keys → create a key
Create a dedicated API key for this integration rather than reusing one. If the Telit org is ever compromised, or a contractor leaves with Developer access, you want to revoke one key without breaking every other integration you run.
Prove the Relay side works
Fire the alert by hand first:
A successful call returns HTTP/2 200, and a task ID:
Devices in maintenance should now be speaking the message every 30 seconds. Tap the talk button on one to acknowledge, or cancel it from the terminal:
If this curl works and the Telit trigger does not, the problem is in the trigger — not in Relay.
Create the Cloud Trigger
In the deviceWISE Cloud portal, go to Developer → Triggers → New Trigger.
Enter the trigger metadata:
Name
Machine down → Relay alert
Description
Voice-alerts the maintenance group when a machine reports a down alarm
Tags
relay, maintenance (optional, but makes triggers findable at scale)
Configure the alarm.change event
Right-click the Start node on the canvas to open Add trigger event, set Event type to alarm.change, and fill in the form.
The alarm.change event fires whenever an alarm changes state.
Time in condition is important to configure
Manufacturing lines microstop constantly. Without debounce, a five-second jam pages four technicians, the alert repeats every 30 seconds, and within a week your maintenance team mutes their Relays.
Time in condition delays execution until the alarm has held the state for the specified number of seconds. The semantics are specific:
If the alarm is republished at the same state during the window, the trigger still executes at the end of the window.
If the alarm changes state during the window — the machine recovers — execution is cancelled.
Sixty seconds is a reasonable opening value for a production line. Tune it to your actual microstop distribution: long enough that self-clearing faults never page anyone, short enough that real downtime is not sitting unreported.
Click Add.
Add the http.client action
Expand the Networking category in the trigger actions list, then click and drag http.client onto the canvas.

Action parameters
Method
POST
URL
https://api.relaypro.com/subscribers/YOUR_SUBSCRIBER_ID/api/v1/alerts
Content type
application/json
Timeout
30
TLS cert
(blank)
TLS key
(blank)
Replace YOUR_SUBSCRIBER_ID with the subscriber ID from Step 2.
Headers
Add one header:
Authorization
RelayApiKey YOUR_API_KEY
The literal string RelayApiKey and a space must precede the key. Authorization: YOUR_API_KEY returns 401.
Body
Select Body: Raw and paste the following. Note that Body: Raw takes precedence over Body: Form — if you populate both, the form is ignored.
Click Add.
Wire the routes and activate
The http.client node has two routing points: left/red is the failure route, right/green is the success route.
Drag a route from the alarm.change event triangle to the 0.http.client action.
Expand the End category and drag a Success node onto the canvas.
Drag the green success route from 0.http.client to the Success node.
Set Reporting mode. The default is On failure, which logs only failed executions. During rollout set it to On to capture every execution — note that On reverts to On failure automatically after 30 days.
Click Add to save the trigger.
Click Start to activate it. A saved trigger does nothing until it is started.
The Triggers list now shows a Success count and Failure count for the trigger. Those two numbers are your first diagnostic.
Payload reference
Relay alert keys
notification and groups are required. Everything else is optional.
notification
string
—
Spoken on every device in the group via text-to-speech.
groups
array
—
Workflow Group names or URNs to alert.
quorum
integer
all devices must acknowledge
Cancels remaining alerts after this many acknowledgements. Set this to 1 for machine-down.
on_ack
string
nothing spoken
Spoken on the device that acknowledged.
on_quorum
string
nothing spoken
Spoken on devices that had not yet acknowledged once quorum is met.
timeout
integer (sec)
300
Cancels remaining alerts after this long.
on_timeout
string
nothing spoken
Spoken on devices that never acknowledged, after timeout.
name
string
alerts
Controls serial/concurrent alerting behavior and appears in analytics events for correlation.
Leaving quorum at its default means the alert keeps sounding on every other device until all of them acknowledge — not needed for a machine-down call where one technician takes the job. Set quorum: 1.
deviceWISE event variables available in the body
From the alarm.change event:
$(event.thing.key)
String
Key of the Thing that fired the trigger
$(event.thing.name)
String
Human-readable name of the Thing
$(event.thing.type)
String
Name of the Thing definition
$(event.alarm.key)
String
Alarm key
$(event.alarm.name)
String
Alarm name
$(event.alarm.msg)
String
Alarm message
$(event.alarm.state)
Integer
Numeric alarm state
$(event.alarm.string)
String
String form of the alarm state
$(event.alarm.ts)
String
Alarm timestamp
$(event.alarm.corrId)
String
Correlation ID
$(event.location.lat)
Float
Latitude of the Thing
$(event.location.lng)
Float
Longitude of the Thing
$(event.location.speed)
Integer
Speed of the Thing
$(event.location.heading)
Float
Heading of the Thing
Two global variables are available in any action: $(trigger.exec_time) and $(time.now). On a failure route you also get $(trigger.lastErrorMsg) and $(trigger.lastErrorCode).
Write for text-to-speech, not for a log file.
$(event.thing.key) is typically a machine-readable key like press_07_lineB. Spoken aloud, that is unintelligible. Use $(event.thing.name) in the notification string allows for more intellible TTS.
For the same reason, avoid interpolating $(event.alarm.msg) into the spoken message unless you control what your gateway writes there. A message field containing an alarm code, a stack trace, or a double quote will produce either gibberish speech or — see the next warning — a 400.
Variable substitution is textual, and the body is JSON.
If an interpolated value contains a double quote, a backslash, or a newline, the substituted body is no longer valid JSON and Relay rejects the request with a 400. Values that originate in a PLC string tag or an operator-entered alarm message are the usual culprits.
For a full execution history, see Telit's Viewing Trigger Report.
Reference
Telit deviceWISE Cloud
Relay
Last updated